Quick Detail

Design standard: API 600.API594 BS1868

Body material: WCB. Carbon Steel

Nominal diameter: 6”DN150

Pressure: CL900LBS

End connection: RF. Flange

Face to face: ASME B16.10.

Working temperature: -29~+425.

Test and inspection: API 598.

Full bore Check valves

High Pin Flat Disc Check Valves

Integral Disc check valves

 

On Request

Available Material: A216WCB/WCC/LCB/WC9/C5/CF8M/CF3

Optional Stem: A182F6a, A182F304, A182F316, F51/F53

Optional Seat & Trim: STL, 2CR13, SS304, SS316/F51

Optional End connection:

Range of valve sizes diameter: 1/2″~60″ (DN15~DN1500).

Range of pressure: 150lbs~2500lbs (PN16~PN420).

Optional: By pass design

Optional Operation: automatic type or Lever and counter weight

 

Performance:

INSPECTION BEFORE INSTALLATION

  1. Before installation, check the valve name plate and valve body information to ensure the valve is suitable for the intended service.
  2. Before installation, remove the flange cover and the protective film on the flange sealing face, and disc support, inspect the bore and the flange sealing surface, remove any dirt with clean soft cloth, use an anti-corrosive cleaning liquid to clean if necessary, and never use any other chemical products.
  3.  Inspect the flange gasket (including ring gasket) sealing surface and ensure it is in acceptable condition for installation. Install Position the valve into the pipe or the flange connection; ensure that any stress caused by improper pipe alignment is relieved first. Valves are not intended to be a means of aligning improperly fitted pipe.2 Valves marked with flow direction must be installed in line with the piping flow.3 Valve should be installed in a horizontal position with the center of the valve.

     

Application:

The medium is water, steam, gas, corrosive medium, oil, medicine, etc.


Product detail pictures:

2020 China New Design Low Temperature Valve -
  A216 WCB 900LBS Check Valve CVC-00900-6 – Deye detail pictures


Related Product Guide:

It can be a great way to enhance our solutions and service. Our mission would be to build inventive products to consumers with a superior working experience for 2020 China New Design Low Temperature Valve - A216 WCB 900LBS Check Valve CVC-00900-6 – Deye , The product will supply to all over the world, such as: Greek , Madrid , Rwanda , Our company has always insisted on the business principle of "Quality, Honest, and Customer First" by which we have won the trust of clients both from at home and abroad. If you are interested in our solutions, you should do not hesitate to contact us for further information.
  • It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 Stars By Beryl from Casablanca - 2017.09.29 11:19
    Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
    5 Stars By Alexandra from Saudi Arabia - 2018.11.06 10:04
    Write your message here and send it to us